ALM-PC 12.01; The controller shows operational but when we start the test, below error message gets displayed:
Question ID: 106064
0
0

There was no end point listening at http://localhost/PCS/PCSLoadTestmanagement.svc that could accept the message.
This is often caused by an incorrect address or SOAP action.

Marked as spam
Posted by (Questions: 231, Answers: 18)
Asked on April 29, 2015 7:19 pm
193 views
Answers (1)
1
Private answer

when thePC Host Controller sends a request to the PC Server,the URL used is ''http://localhost/PCS/PCSLoadTestManagement.svc'' and this request fails, as ''localhost'' is resolved tothe PC Host Controller machine (IP address) and not tothat of thePC Server. As there is no PCSLoadTestManagement.svc service configured on the Host machine the above error message is output.
to correct this :

Use the IP address or the hostname of the PC Server machineinstead of ''localhost''when configuring the internal URL in Lab Management -> PC Servers -> PC Server Details.

Marked as spam
Posted by (Questions: 12, Answers: 384)
Answered on April 29, 2015 7:20 pm