Can’t connect the LoadRunner Controller to the SiteScope machine .
Question ID: 107594
0
0

I'm trying to connect to SiteScope in the LoadRunner Controller under the run tab, I clicked the SiteScope graph, when adding measurements the SiteScope box is not being signed into. I'm getting this DTD is prohibited error.

In the "Add Machine" dialog box, I’m imputing the following values:
Name: SiteScope IP address
Port: 8080
"Use Account" is checked
Account: administrator
Username: admin
Password: "imputing the correct password"

Marked as spam
Posted by (Questions: 144, Answers: 1)
Asked on April 24, 2017 5:26 pm
330 views
Answers (1)
1
Private answer

Your issue is that you are using the wrong port in your SiteScope connection attempt. Please change the port in the ''Add Machine'' dialog to ''8888''. This should resolve your issue.

Marked as spam
Posted by (Questions: 0, Answers: 152)
Answered on April 24, 2017 5:27 pm
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top