Error ”Node not found” when launching UFT from Quality Center
Question ID: 107194
0
0

I am currently using ALM 12.20.378 with UFT 12.02.2374, and when I try to run an automation test remotely from ALM, I get the error "Node not found" on my UFT machine, and the test stops in ALM. I am able to run the same test locally on the UFT machine without any issues. I would also like to add that I have installed TDConnectivity and registered the ALM Client on the UFT machine as well. I do not see where I can change settings for remote execution. Can you help me with this issue?

Marked as spam
Posted by (Questions: 239, Answers: 31)
Asked on October 21, 2016 8:46 pm
138 views
Answers (1)
0
Private answer

I have found where this issue has occurred before with previous versions of UFT, and a patch upgrade resolved the issue. Since you are using UFT 12.02.2374, I would like for you to install patch 6 on the UFT machine, then retest to see if the issue still exists. The patch can be downloaded from the Orasi Support Website by clicking the following link - [UFT_00155 - Patch 6][1].

[1]: https://supportweb.orasi.com/downloads/UFT_00155.zip

Marked as spam
Posted by (Questions: 2, Answers: 300)
Answered on October 21, 2016 8:49 pm
0
The patch resolved the issue. The tests now run remotely without any issues. I appreciate your help with this.
( at October 21, 2016 8:50 pm)