Error: The matrix exceeds the maximum number of core requirements
Question ID: 105738
0
0

When running the traceability report we are getting the error "The matrix exceeds the maximum number of core requirements". Can this limit be increased?

Marked as spam
Posted by (Questions: 122, Answers: 3)
Asked on December 2, 2014 2:39 pm
227 views
Answers (1)
0
Private answer

The tracability matrix is limited due to the performance issues that can occur if the report runs for long periods of time. I believe the limitation is either 2500 or 3000 Requirements (but not seeing it specifically documented). You can normally bypass this limitation in the Site Admin with the below Site Parameter.

**Site Parameter:**
TRACEABILITY_MATRIX_CORE_REQUIREMENTS_FUSE

**Value:**
The value of the total report items

**Example:**

Parameter Name - TRACEABILITY_MATRIX_CORE_REQUIREMENTS_FUSE

Parameter Value - 4000

Marked as spam
Posted by (Questions: 3, Answers: 168)
Answered on December 2, 2014 2:40 pm