Error when accessing ALM-PC QCBIN
Question ID: 109870
0
0

 We are currently using ALM-PC 12.60 and are getting Service Unavailable when accessing qcbin.

Specifically we are receiving 503 error stating the service is unavailable.   I see ALM service is running and I tried restarting the server but still receive the same issue.  Any help on this issue would be great.

Marked as spam
Posted by (Questions: 159, Answers: 15)
Asked on October 24, 2020 1:41 pm
72 views
Answers (1)
0
Private answer

Please restart the "Micro Focus Application Life Cycle Management" service running, and verify all of the following are required services and should be running and set to automatic on all PC servers:

 

  • COM+ services (Event System and System application)
  • DataCollectionAgent
  • Distribution Transaction Coordination
  • IIS Admin service
  • IPSEC Policy Agent
  • RemoteManagement Agent Service
  • Remote Procedure Call (RPC)
  • Secondary Logon
  • System Event Notification (for COM+)
  • TCP/IP NetBIOS Helper
  • Windows Management Instrumentation
  • Windows Event Log
  • Workstation
  • World Wide Web Publishing Services

I hope this helps

Marked as spam
Posted by (Questions: 17, Answers: 266)
Answered on October 24, 2020 1:43 pm