Receiving Error Corralating Test Results in ALM-PC 11
Question ID: 104785
1
0

Using ALM-PC 11, I typically configure tests to "auto collate and analyze" at the end of the test. If auto collate fails then I invoke manual collation and analysis at the end.

Collation is usually successful but the following message pops up when clicking analyze results in the test lab:

Last Run Results:

The project’s host pool must contain a Data Processor host in order to process analysis results.
Add a data processor host to the host pool General, and try again. Do we have a config problem? Any thoughts or input would be great.

Marked as spam
Posted by (Questions: 108, Answers: 6)
Asked on January 4, 2013 2:58 pm
44 views
Answers (1)
1
Private answer

''The project's host pool must contain a Data Processor host in order to process analysis results. Add a data processor host to the host pool General, and try again.''

Please do the following:

1. Login into Performance Center ''Lab Management'' with Admin rights / Privileges

2. Select ''Lab Resources'' and then Click on ''Hosts''

3. Select the appropriate ''Host'' by left clicking

4. Click on the ''Host Details'' Icon button

5. Left Click on the ''Purpose'' field drop down and select ''Data Processor'' and Press the ''Ok'' Button

6. On the Host Details dialog window, press the ''Ok'' button

7. Left click on Hosts at the menu level and select ''Reconfigure Host''

After completing the steps above, you should be able to now analyze the results on the host machine that was just reconfigured.

Marked as spam
Posted by (Questions: 17, Answers: 266)
Answered on January 8, 2013 1:32 pm
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top