TDAPI/OTA – You do not have the required permissions to create the Command object
Tags:
Question ID: 104722
1
0

We are using some TDAPI/OTA code with Qc and are getting this error:
"You do not have the required permissions to create the Command object. Contact your site administrator to make sure that the relevant Command settings are correct."

any ideas on how to stop this and allow API code to work?

Marked as spam
Posted by (Questions: 91, Answers: 5)
Asked on November 27, 2012 3:13 pm
153 views
Answers (1)
1
Private answer

In QC 10 and 11, by default, only users in the TDAdmin group have access to the OTA Command object.
This is necessary to be able to do anything with QC via the TDAPI/OTA.

The Site Administrator optional parameter DISABLE__ COMMAND __INTERFACE controls this.

DISABLE _COMMAND _INTERFACE (no spaces)

If this parameter is set to ''Y'' (default), only users belonging to the TDAdmin group can use the OTA Command object.
If it is set to ''N'', any user can use it.
If it is set to ''ALL'', no users can use it.
For more information, refer to the HP Quality Center Open Test Architecture API Reference.

Marked as spam
Posted by (Questions: 4, Answers: 509)
Answered on November 27, 2012 3:17 pm
EyeOnTesting