When replaying a script on the LG (Win 2012) the script failed?

  • Questions
  • When replaying a script on the LG (Win 2012) the script failed?
Question ID: 107930
1
0

The script is not getting to the website

Version LR 12.55
The Script protocol is Web(http/html)
And works perfectly if the LG is win 7 or win 8.1 and Win 10

Marked as spam
Posted by (Questions: 218, Answers: 15)
Asked on October 25, 2017 4:00 pm
2 views
Answers (1)
2
Private answer

Disable Internet Explorer Enhanced Security Configuration (IE ESC). On
All LGs

- In Windows 2012 R2, 2016: Server Manager > Local Server > Internet Explorer Enhanced Security Configuration.
- In Windows 2008 R2: Server Manager > Security Information > Configure IE ESC.

Marked as spam
Posted by (Questions: 12, Answers: 363)
Answered on October 25, 2017 4:03 pm