Help! Workflow customization is preventing me from logging in to my project!
Question ID: 104156
3
0

How can I rollback the workflow code changes if I cannot login??

Marked as spam
Posted by (Questions: 23, Answers: 1)
Asked on July 14, 2010 7:07 pm
39 views
Answers (1)
3
Private answer

To start Project Customization without logging in to a project:

1) Type the following URL in your Web browser:
testdirector:[server name]:[port number]/qcbin,[domain],[project],
[username];13:[ignore_workflow_parameter]

2) To bypass workflow events, set the value of ignore_workflow_parameter to
''1''. Otherwise, workflow events are triggered.
Only users belonging to the
TDAdmin group can activate this option to bypass workflow events.

For example, suppose that you have user name alex_qc.
You want to
customize the project MyProject in the domain MyDomain on the server
MyServer.

To start Project Customization without triggering workflow
events, type the following URL:
testdirector:MyServer:8080/qcbin,MyDomain,MyProject,alex_qc;13:1

3) When the Quality Center Login window opens, type the password and click
Authenticate.

Marked as spam
Posted by (Questions: 0, Answers: 613)
Answered on July 14, 2010 7:12 pm
0
OH thank goodness. That did the trick! Thankyou Thankyou!
( at July 14, 2010 7:14 pm)
EyeOnTesting