Is it possible to change UDP 5093 for QTP to a more standard Port?
Question ID: 105165
0
0

Since UDP 5093 is non-standard it posses a high degree of vulnerability. The sentinel license manager uses UDP 5093 to issue licenses for QuickTest Pro clients. I would like to change the port to a standard port.

Marked as spam
Posted by (Questions: 1, Answers: 0)
Asked on November 5, 2013 4:59 pm
97 views
Answers (2)
1
Private answer

From http://sentineldiscussion.safenet-inc.com/topic/did-you-know-how-to-change-the-port-used-by-rms:

> How to change the port:
>
> RMS
>
> SentinelLM service runs at port number
> 5093. However you can change the port. If you are running the SentinelLM
> winnt service, you will have to make
> following changes in the registry: run
> 'regedit' and follow the path:
> HKLM->software->rainbow tech.->current
> version->local
>
> Make following entry: CommandLineOpts
> -port change_port
>
> But if you are running 9x server, run
> it with following option: lserv9x
> -port change_port
>
> In your client application after
> VLSinitialize, you should call the
> API, VLSSetServerPort.

Marked as spam
Posted by (Questions: 0, Answers: 771)
Answered on February 3, 2014 9:53 pm
0
Private answer

Yes you can change the port as mentioned above however before changing port I would review the fact that the port is a reserved port by Internet Assigned Numbers Authority (IANA).

http://en.wikipedia.org/wiki/List_of_TCP_and_UDP_port_numbers

Marked as spam
Posted by (Questions: 2, Answers: 98)
Answered on February 4, 2014 1:36 pm