Issue with Custom Actions in Truclient script
Question ID: 107347
0
0

We are using LoadRunner 12.53 and have HTTP/HTML script with around 25 actions and run block to simulate our business usage. We are in the process of creating TruClient script for this application. We are not able to add more than 10 additional actions in TruClient script. We are receiving an error stating that maximum number of actions have been reached. Is there any way to configure TruClient to change the max actions allowed in TruClient or is there any other workaround?

Marked as spam
Posted by (Questions: 159, Answers: 15)
Asked on January 18, 2017 2:50 pm
125 views
Answers (1)
2
Private answer

Unfortunately, there is no configuration that can be done to change the max actions. Ten actions is the current limit and there is not a work around at this time. You will need to use the Web protocol.

In addition, when using the TruClient protocol, the footprint can be significantly larger than the footprints of other Vuser protocols. This larger footprint will require more CPU and memory capacity than would be required to run a similar business process recorded in another protocol.

Marked as spam
Posted by (Questions: 17, Answers: 266)
Answered on January 18, 2017 2:51 pm
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top