LeanFT Failed to connect to LeanFT runtime engine on remote machine
Question ID: 107121
1
0

We are trying to run our LeanFT tests on a remote machine but we keep getting this error:

ERROR Connect: Failed to connect to LeanFT runtime engine on ws://10.0.4.13:5095/.
CoHP.LFT.Communication.SocketClient.CommunicationException: nnect: Failed to connect to LeanFT runtime engine on ws://10.0.4.13:5095/.

We think we have set it up according to HPE instructions at [http://leanft-help.saas.hp.com/en/12.53/HelpCenter/Content/HowTo/RunRemotely.htm][1], but it still does not work. Any ideas?

[1]: http://leanft-help.saas.hp.com/en/12.53/HelpCenter/Content/HowTo/RunRemotely.htm

Marked as spam
Posted by (Questions: 387, Answers: 66)
Asked on September 28, 2016 3:04 pm
692 views
Answers (1)
0
Private answer

Everything I have found regarding this error states that either the runtime engine is not running or there is something blocking or using the port (5095).

Please confirm the runtime engine is running on the remote machine prior to trying to run the test, and please check with your network team about the port (both on the local machine and the remote machine). If something else is using the port, you can change the port configuration for LeanFT using the instructions at [https://softwaresupport.hpe.com/document/-/facetsearch/document/KM02540006][1]

[1]: https://softwaresupport.hpe.com/document/-/facetsearch/document/KM02540006

Marked as spam
Posted by (Questions: 17, Answers: 807)
Answered on September 28, 2016 3:04 pm
0
Our port was being used by another application. Changing the port worked. Thanks.
( at September 28, 2016 3:08 pm)