Release and Cycle fields contain incorrect values Quality Center v9.2
Question ID: 104078
5
0

Window and Emails Release and Cycle fields contain incorrect values Quality Center v9.2.

Marked as spam
Posted by (Questions: 23, Answers: 1)
Asked on April 5, 2010 6:00 pm
60 views
Answers (1)
3
Private answer

This is a know issue for all projects created before QCv92 patch 12.

To correct the issue:

1) Install the latest patch (After Patch 12)

2) Perform an upgrade process in Site Administrator for each project experiencing the issue.

3) Login to Site Administrator

4) Highlight the project

5) Right Click and select Upgrade Project from the menu.

6) Answer the Prompts

7) If a message appears stating the project is already upgraded, select the option to perform the upgrade again.

Marked as spam
Posted by (Questions: 0, Answers: 613)
Answered on April 5, 2010 6:02 pm