Votes
Answers
Views
Question
7
votes
1
answer
238
views
asked 14 years ago by
updated 14 years ago by
When using HP LoadRunner to Record a SAPGUI script. How does one enable the Scripting interface within SAP server?
2
votes
1
answer
835
views
asked 14 years ago by
updated 14 years ago by
Hello all, Thanks for the great answers. I've definitely benefited from the site's expertise and easy to navigate format. Is there an easy way to view run-time data after a VuGen script is complete (only in TryScript mode)? I want to see which parameters were used, certain correlated values, etc aft...
0
votes
2
answers
1597
views
asked 14 years ago by
updated 11 years ago by
I am getting the following error on several, but not all, Vusers during a 1000 Vuser load test. Most but not all are crapping out at about the same iteration (23). However, when I test and run the script from VUgen, it goes through all 73 values of {SearchTerm} with no errors. Is there a way to see ...
6
votes
6
answers
971
views
asked 14 years ago by
updated 6 years ago by
When setting up the LB and RB strings for capturing a dynamic value with web_reg_save_param(), is there a way to have the boundaries ignore whitespace and newlines? EDIT (more info): I'm trying to capture a dynamic value and the left bound would be the following (as returned by the server): <div ...
2
votes
1
answer
28
views
asked 14 years ago by
updated 14 years ago by
For debugging purposes, I have a long web(http/html) script that I would like to have ignore think times for the first part of the script on playback, but then enable them when it reaches the section I'm interested in. Is there a way to do this without commenting out all the think times up to that p...
3
votes
1
answer
874
views
asked 14 years ago by
updated 14 years ago by
I am working on a script that has an address for an input. The address is setup as a parameter coming from a data file. Part of the request that is sent replaces all of the spaces in the address with %20. I've tried a few ways to do it but either it does not work or I get an memory access violation ...
1
vote
1
answer
767
views
asked 14 years ago by
updated 14 years ago by
I need to set the Network Buffer Size Runtime setting via code. This setting is found in the Runtime Settings -> Internet Protocol -> Preferences -> Options -> General -> Network Buffer Size Is this possible using one of the build in web_* or lr_* functions? -Terri
5
votes
1
answer
72
views
asked 15 years ago by
updated 15 years ago by
Vugen Crashing with EXCEPTION_ACCESS_VIOLATION in module MFC80.DLL
3
votes
6
answers
51
views
asked 15 years ago by
updated 14 years ago by
I would like to know if anyone has had problems recording with LoadRunner 9.52 against IE8 browser.
1 11 12 13
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top