Votes
Answers
Views
Question
1
vote
2
answers
1142
views
asked 15 years ago by
updated 13 years ago by
hello, Can someone provide a good example of when and how the globals.h file would be used? I've also been told that in order to create an effective data repository to be used across multiple scripts, yet another piece of software called HP VTS (Virtual Table Server) has to be utilized. Is this the ...
6
votes
6
answers
1086
views
asked 15 years ago by
updated 7 years ago by
When setting up the LB and RB strings for capturing a dynamic value with web_reg_save_param(), is there a way to have the boundaries ignore whitespace and newlines? EDIT (more info): I'm trying to capture a dynamic value and the left bound would be the following (as returned by the server): <div ...
6
votes
1
answer
58
views
asked 15 years ago by
updated 15 years ago by
we are working on the LoadRunner 9.52 SAPGUI configuration. We have done the following configuration settings in the Load Controller. Load Controller -> Add Measurements->Add Machine -> Server physical name added In Add Resource Measurement -> SAP Logon window -> Login, Password, Server Name and Cli...
2
votes
1
answer
46
views
asked 15 years ago by
updated 15 years ago by
For debugging purposes, I have a long web(http/html) script that I would like to have ignore think times for the first part of the script on playback, but then enable them when it reaches the section I'm interested in. Is there a way to do this without commenting out all the think times up to that p...
3
votes
1
answer
983
views
asked 15 years ago by
updated 15 years ago by
I am working on a script that has an address for an input. The address is setup as a parameter coming from a data file. Part of the request that is sent replaces all of the spaces in the address with %20. I've tried a few ways to do it but either it does not work or I get an memory access violation ...
3
votes
1
answer
617
views
asked 15 years ago by
updated 15 years ago by
I am running a very basic script in PeopleSoft the script is the login and read the home page then logout I am getting this error has anyone see this before?? and how do I fix it?? Login.c(7): Error -26000: rc=-1/WSAGetLastError=10038 from WSAEventSelect(_nSocketFD=4294967295, _pvEvent=00000000, mui...
2
votes
1
answer
39
views
asked 15 years ago by
updated 15 years ago by
I have 9.52 Vugen installed and try to record in Firefox but "Program to Record" shows only IE and not Firefox. How do I record using the FireFox browser?
5
votes
3
answers
1262
views
asked 15 years ago by
updated 11 years ago by
I have a recurring problem with a particualr LR controller and file transfer issues. I can create scripts in VuGen and name them with a long, descriptive file name like WebMethodContract_WebServiceName. One controller will sometimes have issues with this and give me a WSDL file transfer error. I can...
1
vote
1
answer
41
views
asked 15 years ago by
updated 15 years ago by
I am having a problem with the agent process (magentproc.exe) running with more than 1 user logged on the generator. If the process was already running under another user I have to kill the process through the task manager. Otherwise the tests will fail for file transfer issues. If I try to start it...
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top