After upgrading to PC 12.62, Unable to connect project in VUGEN to ALM File Repo.
Question ID: 108967
0
0

We just upgraded to PC 12.62 and have verified that all my users can login to the My PC for their projects; however, no one is able to connect to new ALM_PC, projects from within VuGen.

When I go into VUGEN and click **"Version control" ->ALM ->ALM Connection** enter the server, username and password. I’m getting the message "User is currently not associated with any project" (see attached file). I’ve added my user to the project.
![alt text][1]

[1]: /storage/temp/946-eotpic1.png

Marked as spam
Posted by (Questions: 231, Answers: 18)
Asked on April 26, 2019 3:35 pm
77 views
Answers (1)
1
Private answer

Please Verity that your VuGen is the Same version as the ALM-PC 12.62

VuGen 12.55 will not connect to ALM-PC 12.60+ until upgrading of the VuGen to 12.62 is done ( or matching version). Before using the VuGen connect to ALM option. The versions must be the same.

Marked as spam
Posted by (Questions: 12, Answers: 384)
Answered on April 26, 2019 3:38 pm
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top