HP UFT and Web Browser with ALM
Question ID: 106661
1
0

Windows opened before UFT is launched used to be ignored and only windows opened after were recognized. In our latest version UFT can also see windows opened prior to opening UFT. This has become an issue is running tests from Quality Center (ALM) which must be opened in IE. When UFT runs a script it sees the ALM window. It didn’t used to do that.

This is currently a major issue

Marked as spam
Posted by (Questions: 424, Answers: 91)
Asked on January 29, 2016 2:27 pm
58 views
Answers (2)
1
Private answer

Open UFT, and with a GUI test with Web Add-in open, go to Tools menu > Options > GUI Testing > Web (on the left-hand pane) > Web/General > Check/enable ''Ignore ALM'' > Click OK > Close UFT

Marked as spam
Posted by (Questions: 0, Answers: 771)
Answered on January 29, 2016 2:27 pm
0
The resolution resolved the issue
( at January 29, 2016 2:28 pm)
0
Private answer

@ruckjames Open UFT, and with a GUI test with Web Add-in open, go to Tools menu > Options > GUI Testing > Web (on the left-hand pane) > Web/General > Check/enable ''Ignore ALM'' > Click OK > Close UFT ------
How can we do the same settings through script.
I mean by creating object of QTP and check ''ignore ALM'' check box, through script.
Please mail me amanjain42@gmail.com

Marked as spam
Posted by (Questions: 0, Answers: 1)
Answered on May 15, 2018 8:44 am