Use SiteScope (instead of SiteScope for Load Testing) with Performance Center
Question ID: 108907
0
0

We have installed SiteScope 11.51 Enterprise, instead of SiteScope for Load Testing, and want to use the SiteScope server for integrating with the Topology feature, in Performance Center 12.6x, without reinstalling it.

Marked as spam
Posted by (Questions: 144, Answers: 1)
Asked on March 25, 2019 1:01 pm
22 views
Answers (1)
0
Private answer

SiteScope has a minimum monitor frequency of 15 seconds, which is usually too long for working with Performance Center.

On the SiteScope Server, add the following entries to the master.config file. Alternatively, you can add them in the Infrastructure Preferences page.

_monitorMinInterval=1

_topazPageSkipEmptyValues=true

_maxMonitorSkips=60

_shutdownOnSkips=

Note: The maxMonitorSkips=60 and shutdownOnSkips= properties may affect SiteScope monitors which are unrelated to performance testing.

Marked as spam
Posted by (Questions: 0, Answers: 152)
Answered on March 25, 2019 1:03 pm
EyeOnTesting

Welcome back to "EyeOnTesting" brought to you by Orasi Software, Inc.

X
Scroll to Top