2
votes
1
answer
44
views
asked 12 years ago by
updated 12 years ago by
Using ALM-PC 11, I typically configure tests to "auto collate and analyze" at the end of the test. If auto collate fails then I invoke manual collation and analysis at the end. Collation is usually successful but the following message pops up when clicking analyze results in the test lab: La...
2
votes
1
answer
22
views
asked 8 years ago by
updated 8 years ago by
When I run the System Health Check in Lab Management, the entry "Check SiteScope integration" always fails. We upgraded our SiteScope to a new server and version. Ever since the upgrade, this check has failed. Where do you change the location of SiteScope servers in ALM? We looked in Lab Man...
2
votes
3
answers
263
views
asked 6 years ago by
updated 6 years ago by
In All our ALM Performance Center Servers, Controllers and Load generators we have LOCAL iusr_test user account along with iusr_metro account. Now my security team wants to remove all the local accounts, please let us know removing of local user account will impact our performance center environment...
2
votes
1
answer
32
views
asked 5 years ago by
updated 5 years ago by
We are trying to use the "Update" option in the Micro Focus licensing portal to update our LoadRunner v12.55 license to v12.60. Everything seems fine to where we select our assets, select Update, provide the locking information/Host ID, but when we click the final Update button, nothing seem...
2
votes
1
answer
152
views
asked 5 years ago by
updated 5 years ago by
Is there a quick-start guide for managing my Micro Focus software licenses? It all seems very confusing to me.
2
votes
1
answer
23
views
asked 5 years ago by
updated 5 years ago by
How to I use my free SiteScope for load testing license (included with LoadRunner and Performance Center)?
2
votes
2
answers
55
views
asked 5 years ago by
updated 5 years ago by
We recently upgraded to ALM-PC 12.62, and now when in My Performance Center and Performance Center Administration, we are now having to log back in after being idle for one hour. Is there any way to disable this feature?
2
votes
1
answer
54
views
asked 5 years ago by
updated 5 years ago by
Please clarity what does this message mean? . "Passed -- Check connectivity between the Controller and load generators - No check done - this host is not set as Controller purpose"
2
votes
1
answer
49
views
asked 4 years ago by
updated 4 years ago by
Can we remove the 'Create Global Objects' permission for the LRE system user account?   The information security team has informed us that the domain service account we use for LRE currently has the 'Create Global Objects' right applied.   on our LRE server in Local Security Policy ->  Windows Se...